Product parameter table
Diesel generator parameters for Nigeria.
View common generator parameters, then confirm final engine, alternator, voltage and canopy configuration before quotation.
Parameter Table
Typical models for reference. Final specification depends on engine, alternator and site load.
| Model | Prime Power | Standby Power | Engine Option | Voltage / Frequency | Fuel Tank | Canopy / Type | Typical Use |
|---|
Full-range parameter directory
Every rating this site covers, grouped by class. Final specification depends on engine, alternator, controller and site conditions.
| Rating | Output at 0.8 PF | Class | Detail |
|---|---|---|---|
| 10kVA | 8 kW | Small commercial | Parameter page |
| 12kVA | 10 kW | Small commercial | Parameter page |
| 15kVA | 12 kW | Small commercial | Parameter page |
| 20kVA | 16 kW | Small commercial | Parameter page |
| 25kVA | 20 kW | Small commercial | Parameter page |
| 30kVA | 24 kW | Small commercial | Parameter page |
| 40kVA | 32 kW | Commercial | Parameter page |
| 45kVA | 36 kW | Commercial | Parameter page |
| 50kVA | 40 kW | Commercial | Parameter page |
| 60kVA | 48 kW | Commercial | Parameter page |
| 75kVA | 60 kW | Commercial | Parameter page |
| 80kVA | 64 kW | Commercial | Parameter page |
| 100kVA | 80 kW | Commercial | Parameter page |
| 125kVA | 100 kW | Light industrial | Parameter page |
| 150kVA | 120 kW | Light industrial | Parameter page |
| 160kVA | 128 kW | Light industrial | Parameter page |
| 165kVA | 132 kW | Light industrial | Parameter page |
| 200kVA | 160 kW | Light industrial | Parameter page |
| 250kVA | 200 kW | Light industrial | Parameter page |
| 300kVA | 240 kW | Light industrial | Parameter page |
| 350kVA | 280 kW | Industrial | Parameter page |
| 400kVA | 320 kW | Industrial | Parameter page |
| 500kVA | 400 kW | Industrial | Parameter page |
| 600kVA | 480 kW | Industrial | Parameter page |
| 700kVA | 560 kW | Industrial | Parameter page |
| 800kVA | 640 kW | Industrial | Parameter page |
| 1000kVA | 800 kW | Industrial | Parameter page |
How to use this parameter table
This page is a directory rather than a product. It exists because the numbers a buyer needs before requesting a quotation are spread across the range: a 20kVA shop set and a 500kVA factory set are different machines with different engines, different enclosures and different installation requirements, but they are described with the same handful of fields.
The table below lists every rating this site covers, the output each delivers at a planning power factor of 0.8, and the parameter page that describes that size. Read it as an index. The parameter page for the rating you are considering will give the detail that matters at that size.
The parameter view above this section is interactive: it filters by range. What follows is the same information in a form that can be read without it, because a specification should not depend on a browser feature.
Reading kVA, kW and power factor off a nameplate
Almost every misunderstanding between a buyer and a supplier starts with these three fields. A set is sold in kVA, the site is planned in kW, and the link between them is the power factor.
At the conventional planning power factor of 0.8, the kW figure is four fifths of the kVA figure. A 250kVA set is a 200 kW machine. If the site's load presents a power factor below 0.8, the usable kW at the same kVA falls further, which is why a set that looks generous on paper can be tight in service.
Beyond the arithmetic, three conventions change what a nameplate actually promises: whether the figure is prime or standby, the ambient temperature the rating was declared at, and whether the set is declared for continuous or intermittent duty. Two sets with identical kVA can differ on all three.
Prime, standby and the ambient question
Prime output is the figure a set can hold continuously, with a stated overload allowance for a limited period. Standby output is a higher, short-duration figure with no sustained overload allowance. A site that runs the generator through a working day is buying the prime figure, whatever the quotation headline says.
The ambient question is the one buyers ask least often and regret most. A rating declared at a temperate reference condition is not the rating a set holds in a hot, humid compound with restricted airflow. Ask for the output at the condition the site will actually see, and for the radiator specification that goes with it.
These two conventions together explain most of the gap between a specification that reads well and an installation that underperforms. Neither is a trick: they are simply fields that are easy to leave unstated.
Engine options across the range
Engine platform choices differ by rating band, and so does the reason for choosing one.
Small commercial ratings
At the small end, buyers usually value parts commonality and simplicity over badge. A dealer running several small sets for hire or resale will often standardise on one platform so that filters and consumables fit everything on the yard.
Commercial ratings
In the commercial band the engine choice is more visible in operation. Displacement at the rating determines torque reserve, and torque reserve is what the buyer feels as a calm recovery when a motor starts. Two engines at the same kVA can differ noticeably here.
Industrial ratings
At the top of the range the set is specified rather than selected from a catalogue. The engine is matched to a load study, the alternator is matched to the engine, and the support organisation behind the platform matters more than the badge on the canopy.
Cummins, Perkins and Yuchai all appear across these bands on this site. What changes is not the availability of an engine but the specification around it: the alternator, the controller, the cooling package and the enclosure.
Enclosure choice by rating
An enclosure is a thermal decision before it is an acoustic one. The engine and radiator reject heat into the space the canopy occupies, and the canopy has to remove it without pulling it back in.
At small ratings a generic canopy usually works, because the heat load is modest. As the rating rises, the canopy becomes a designed component: specific intake area, a ducted discharge, baffled acoustic panels, and access doors positioned where a technician needs them.
Open sets remain a legitimate choice for sites with a plant room, but the room then carries the acoustic and ventilation requirements instead. Buyers who choose open to save on the enclosure frequently spend the difference on the room, and discover it late.
ATS, paralleling and control
Whether a set needs an automatic transfer switch, and whether it should be capable of paralleling, are controller and switchgear questions rather than engine questions.
For a single set covering a whole building, one ATS rated for the site peak is the normal arrangement. Confirm whether it switches the neutral, and whether the controller has the output to drive it. A capable controller driving nothing is a common and avoidable waste.
Paralleling buys redundancy and lets a site run one machine at a sensible load instead of two at a poor one. It requires controllers designed to synchronise, matching switchgear and a load-sharing scheme. If there is any prospect of a second set later, raise it before the order; retrofitting is expensive.
Installation parameters that are not on the datasheet
A datasheet describes a set on a test bed, not a set in a compound. These are the parameters that decide whether the installation delivers what the paper promises.
- Combustion air supplied from outside the enclosure, independent of general room ventilation.
- Radiator discharge ducted away from the intake, so hot air cannot recirculate.
- A level, drained plinth with anti-vibration mounts rated for the set.
- Exhaust run as short as the layout allows, insulated, and terminated away from openings.
- A bunded fuel tank with isolation and a water separator at the engine.
- Service access on the sides a technician actually needs, not only the front.
Documents that should accompany the set
The document pack is part of the specification. Ask for the list before the order, because assembling it afterwards is slower and sometimes impossible.
- A load test record showing output, voltage, frequency and temperatures at stated load steps.
- Nameplate photographs for the engine, alternator and controller, matching the approved datasheet.
- The controller settings sheet as commissioned.
- A wiring diagram that matches the build rather than a generic drawing.
- The consumables list with part numbers, so the first service can be planned.
- A packing list, and loading photographs for consolidated consignments.
FAQ
What does the parameter table on this page show?
It shows the ratings this site covers, the output each delivers at a planning power factor of 0.8, the class each rating belongs to, and the parameter page that describes that size in detail. It is a directory, not a quotation.
Why does the same kVA give a different kW on two datasheets?
Because the kW figure depends on the power factor the set is rated at. At 0.8 the kW is four fifths of the kVA. If a datasheet declares a different power factor, or declares a different ambient condition, the kW figure changes with it.
Is prime or standby rating the one I should plan against?
Prime, if the generator will run through a working day. Standby output is a higher short-duration figure with no sustained overload allowance, and it is not a figure for continuous running.
Can I get a datasheet for one specific rating?
Yes. Each rating has a parameter page listed in the table above, and a datasheet for the exact configuration can be issued once the duty, engine platform, enclosure and delivery basis are confirmed.
Does the parameter table include a price?
No. Price depends on the specification, the quantity, the delivery basis and the port, so it is quoted against a stated requirement rather than published as a table.
Which engine platforms are available across the range?
Cummins, Perkins and Yuchai appear across the bands described on this site, alongside other options at particular ratings. What differs between them at a given kVA is displacement, fuel system, and the service path available where the set will stand.
Why is the interactive table above not enough on its own?
Because it is filtered by a browser. The static directory below it carries the same ratings in server-rendered HTML, so the information and the links remain readable to any client that does not run scripts.
Get a written quotation
Three fields. We reply with the rating, the engine option and the delivery basis.