WhatsApp: +86 157 0593 2345Email: miu@taiyudapu.comCall the factory: +86 157 0593 2345
Diesel generator product range

10-30kVA Diesel Generators for Nigeria

This is the band where a generator is bought to protect a defined list rather than to power a process. A shop, a villa, a small clinic or a light farm load all fit here, provided the one or two motor loads in the list have been identified rather than discovered later.

Rows of compact white silent generator enclosures in our factory workshop
The photograph shows an open generator assembly with radiator, engine, alternator and control cabinet. Suitability for a specific site still depends on the load list and the written quotation.
Selection principle

No fixed price applies across a small backup range, because a 10kVA and a 30kVA set are different machines serving different loads, and a single 30kVA site can be quoted as silent or open, with or without changeover.

What a set in this band is expected to carry

These sets are usually bought to protect essential circuits, not every circuit. The practical task is to decide which circuits those are, and to count the motors among them.

Lighting, sockets, a fridge or freezer, a computer or POS terminal and a fan are all easy. A borehole pump, a small compressor, a welding set or an air conditioner are not, because each draws several times its running current for a moment at start.

One working rule helps at this size: list the loads, mark the largest motor, and check whether the set can start that motor while everything else is already running. If it cannot, either the start must be sequenced or the rating must move up.

Reference configurations in this band

The table is a reference point from the product directory, not a final sizing decision. Values should be confirmed against the written quotation, and voltage and phase must be confirmed for the actual site.

Reference configurations in this band
ModelPrime ratingStandby ratingEngine optionTypical outputExample use
NGS-1010kW / 12.5kVA11kW / 14kVAPerkins or selected Chinese engine220/380V, 50HzShop, office, villa
NGS-2020kW / 25kVA22kW / 28kVAYangdong or Ricardo option220/380V, 50HzSmall business backup
NGS-3030kW / 37.5kVA33kW / 41kVACummins or Weichai option220/380V, 50HzClinic, farm, light load

Deciding between silent and open at this size

Small sets sit closer to people, so the enclosure question arrives earlier here than it does at industrial ratings. A shop front, a clinic compound or a residential boundary is not an industrial plant room.

An open set needs a room with real ventilation and an exhaust route, and it is quieter to buy and easier to service. A sound-attenuated canopy buys placement freedom and lower site noise, at higher cost and weight.

Either way, ventilation matters more than buyers expect, because the set has to reject heat continuously. A canopy that blocks airflow will derate the machine it is meant to protect.

What to confirm before payment

Confirm the voltage and phase, the rating basis, the enclosure type, whether a changeover panel is included, and what the delivery term covers. Ask for the offered engine option by name rather than by brand alone.

Before releasing funds, verify the supplier's identity, the invoice issuer and the beneficiary details, and agree in writing which documents and photographs will accompany the shipment.

Related: 10kW diesel generator buying guide, 10kW fuel consumption guide, single phase vs three phase, 10kW generator with ATS.

Get a written quotation

Three fields. We reply with the rating, the engine option and the delivery basis.

Send on WhatsApp

WhatsApp RFQ template

Hello, I need a 10-30kVA diesel generator quote for Nigeria. Load list: [ ], largest motor or air conditioner: [ ], single or three phase: [ ], silent or open: [ ], ATS: [yes/no], quantity: [ ], delivery: [CIF Lagos/FOB China].

Send this RFQ on WhatsApp

Small range questions

Is a 10kW generator the same as 10kVA?

No. The two are related by the power factor. A 10kW output corresponds to roughly 12.5kVA at a 0.8 power factor, which is why the reference configuration in this band is listed as both.

Can a set in this band include automatic changeover?

Yes, where a matched transfer panel and the control wiring are part of the order. The changeover scope should be stated explicitly, because it is one of the items most often assumed rather than priced.

Should the set be single phase or three phase?

Follow the load distribution rather than the size of the set. A site whose heavy loads are three-phase motors should stay three-phase, while a site dominated by domestic circuits may be better served by a single-phase arrangement.